Sulb-1032, Sulb-1033, Sulb-1034 – Dell POWEREDGE M1000E User Manual

Page 695: Sulb-1035

background image

Fabric OS Message Reference

619

53-1001767-01

SULB-1032

97

Recommended

Action

Wait for the operation to complete.

Severity

WARNING

SULB-1032

Message

, [SULB-1032], , AUDIT, WARNING, ,

Relocating an internal firmware image on the CP.

Probable Cause

Indicates the switch has started a firmware download to the co-CPU.

Recommended

Action

Wait for the operation to complete.

Severity

WARNING

SULB-1033

Message

, [SULB-1033], , AUDIT, WARNING, ,

Switch has completed relocating the internal firmware image.

Probable Cause

Indicates the firmwareDownload process has completed normally on the switch.

Recommended

Action

Run the firmwareShow command to verify the firmware versions. Run the switchShow command to
make sure the switch is enabled.

Severity

WARNING

SULB-1034

Message

, [SULB-1034], , AUDIT, ERROR, ,

Relocation of internal image timed out.

Probable Cause

Indicates there may be an error caused by the switch initialization issue after the internal image is
relocated. It may also be caused by the internal Ethernet issue or by persistent storage failure.

Recommended

Action

Restart the switch. This will cause the internal image to be relocated again. Use the
firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your
switch service provider.

Severity

ERROR

SULB-1035

Message

, [SULB-1035], , AUDIT, ERROR, , An

error has occurred during relocation of the internal image.