FW-1052

42

Recommended

Action

Frequent voltage fluctuations are an indication that the SFP is deteriorating. Replace the SFP.

Severity

WARNING

FW-1052

Message

, [FW-1052], ,, INFO, ,

between high and low boundaries(High=, Low=). Current value

is .

Probable Cause

Indicates that the value of the small form-factor pluggable (SFP) voltage has changed from a value
outside of the acceptable range to a value within the acceptable range.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.

Severity

INFO

FW-1113

Message

, [FW-1113], ,, INFO, ,

has changed(High=, Low=). Current value is .

Probable Cause

Indicates that the number of times E_Ports have gone down has changed. E_Ports go down each
time you remove a cable or small form-factor pluggable (SFP). SFP failures also cause E_Ports to go
down. E_Port downs might be caused by transient errors.

Recommended

Action

Check both ends of the physical connection and verify that the SFPs and cables are functioning
properly.

Severity

INFO

FW-1114

Message

, [FW-1114], ,, INFO, ,

below low boundary(High=, Low=). Current value is

.

Probable Cause

Indicates that the number of times E_Ports have gone down has fallen below the low boundary.
E_Ports go down each time you remove a cable or small form-factor pluggable (SFP). SFP failures
also cause E_Ports to go down. E_Port downs might be caused by transient errors. A low number of
E_Port failures means that the switch is functioning normally.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.

Severity

INFO