Fabr-1016, Fabr-1017, Fabr-1018 – Dell POWEREDGE M1000E User Manual
Page 256: Fabr-1019

180
Fabric OS Message Reference
53-1001767-01
FABR-1016
26
FABR-1016
Message
is enabled.
Probable Cause
Indicates that FICON mode is enabled on the switch through a user interface command.
Recommended
Action
No action is required.
Severity
WARNING
FABR-1017
Message
is disabled.
Probable Cause
Indicates that FICON mode is disabled on the switch through a user interface command.
Recommended
Action
No action is required.
Severity
WARNING
FABR-1018
Message
principal failed ( principal switch>). Probable Cause Indicates that a failure occurred when trying to set the principal switch using the fabricPrincipal • The switch joined an existing fabric and bypassed the F0 state. • The fabric already contains a principal switch that has a lower world wide name (WWN). Recommended Action Make sure that no other switch is configured as the principal switch. Force a fabric rebuild by using Refer to the Fabric OS Command Reference for more information about the fabricPrincipal Severity WARNING FABR-1019 Message Critical fabric size ( (
command. The message notifies you that the switch failed to become the principal switch because
of one of the following reasons:
the switchDisable and switchEnable commands.
command.