Sec-1115, Sec-1116, Sec-1117 – Dell POWEREDGE M1000E User Manual
Page 605: Sec-1118

Fabric OS Message Reference
529
53-1001767-01
SEC-1115
90
SEC-1115
Message
to failover.
Probable Cause
Indicates that during an attempted secFcsFailover, no primary fabric configurations server (FCS) is
present in the fabric.
Recommended
Action
Run the secFabricShow command to verify that all switches in fabric are in the ready state. When
all switches are in the ready state, retry the operation.
Severity
ERROR
SEC-1116
Message
failover.
Probable Cause
Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity
ERROR
SEC-1117
Message
.
Probable Cause
Indicates the switch failed to save the data received by the primary fabric configuration server
(FCS) switch. This data can be an FCS password, a non-FCS password, SNMP data, or multiple user
authentication data.
Recommended
Action
Run the secFabricShow command to verify that all switches in the fabric are in the ready state.
When all switches are in the ready state, retry the operation.
Severity
INFO
SEC-1118
Message
SNMP string.
Probable Cause
Indicates the SNMP string could not be set.