Fabric OS Message Reference

53-1001767-01

FW-1177

42

FW-1177

Message

, [FW-1177], ,, INFO, , ,

is .

Probable Cause

Indicates that the number of invalid words that the port experiences has fallen below the low
boundary. Invalid words usually indicate a hardware problem with an small form-factor pluggable
(SFP) or cable. A low number of invalid words means that the switch is functioning normally.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.

Severity

INFO

FW-1178

Message

, [FW-1178], ,, WARNING, , ,

is .

Probable Cause

Indicates that the number of invalid words that the port experiences has risen above the high
boundary. Invalid words usually indicate a hardware problem with an small form-factor pluggable
(SFP) or cable.

Recommended

Action

Check both ends of your connections, your SFP, and your cable to verify that none are faulty.

Severity

WARNING

FW-1179

Message

, [FW-1179], ,, INFO, , ,

Current value is .

Probable Cause

Indicates that the number of invalid words that the port experiences has changed from a value
outside of the acceptable range to a value within the acceptable range. Invalid words usually
indicate a hardware problem with an small form-factor pluggable (SFP) or cable.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.

Severity

INFO

FW-1180

Message

, [FW-1180], ,, INFO, , ,

.