Fabric OS Message Reference
27
53-1001767-01
AG-1008
2
Recommended
Action
Check the connectivity between the Access Gateway N_Port and the fabric switch port.
Severity
WARNING
AG-1008
Message
login (PLOGI) response from the fabric on the N_Port
Probable Cause
Indicates the fabric switch management server did not accept the N_Port Login (PLOGI) request
sent by the Access Gateway.
Recommended
Action
Check the configuration of the fabric switch connected to the Access Gateway.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity
WARNING
AG-1009
Message
failed on N_Port
Probable Cause
Indicates there was a failure sending a Fabric Login (FLOGI) request from the Access Gateway to
the fabric switch.
Recommended
Action
Please check the configuration of the fabric switch connected to the Access Gateway.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity
WARNING
AG-1010
Message
failed on N_Port
Probable Cause
Indicates there was a failure sending an N_Port Login (PLOGI) request from the Access Gateway to
the fabric switch.
Recommended
Action
Check the configuration of the fabric switch connected to the Access Gateway.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity
WARNING