Fabric OS Message Reference

341

53-1001767-01

FW-1425

42

Recommended

Action

Run the switchStatusShow command to determine the policy violation.

Severity

WARNING

FW-1425

Message

, [FW-1425], ,, INFO, , Switch status

changed from

to HEALTHY.

Probable Cause

Indicates that the switch status has changed to a healthy state. This occurred because a policy is
no longer violated.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.

Severity

INFO

FW-1426

Message

, [FW-1426], ,, WARNING, , Switch status

change contributing factor Power supply: bad,

absent.

Probable Cause

Indicates that the switch status is not in a healthy state. This occurred because the number of
faulty or missing power supplies is greater than or equal to the policy set by the
switchStatusPolicySet command.

Recommended

Action

Replace the faulty or missing power supply.

Severity

WARNING

FW-1427

Message

, [FW-1427], ,, WARNING, , Switch status

change contributing factor Power supply:

bad.

Probable Cause

Indicates that the switch status is not in a healthy state. This occurred because the number of
faulty power supplies is greater than or equal to the policy set by the switchStatusPolicySet
command.

Recommended

Action

Replace the faulty power supply.

Severity

WARNING