Sulb-1022, Sulb-1023, Sulb-1024 – Dell POWEREDGE M1000E User Manual
Page 693

Fabric OS Message Reference
617
53-1001767-01
SULB-1022
97
SULB-1022
Message
in slot
Probable Cause
Indicates that the blade in the specified slot has rebooted with new firmware. This is a normal step
in the firmwareDownload process.
Recommended
Action
Run the firmwareDownloadStatus command to monitor the firmwareDownload progress.
Severity
WARNING
SULB-1023
Message
number> has rebooted during firmwaredownload. Probable Cause Indicates there may be an error caused by an unexpected disruption of the firmwareDownload Recommended Action The firmwareCommit will be started automatically after the blade boots up to repair the secondary Severity WARNING SULB-1024 Message completed on the blade in slot Probable Cause Indicates the firmwareCommit operation has completed on the specified blade. Recommended Action Run the firmwareShow command to verify the firmware versions. If the blade firmware is the same Severity WARNING
command, for example, by powering off and on of the indicated BP blade in the middle of a
firmwareDownload. The error may also be caused by persistent storage hardware failure or by a
software error.
partition. If at the end of firmwareCommit, the blade firmware version is still inconsistent with the
active CP firmware, firmwareDownload will automatically be restarted on the blade. Run the
firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your
switch service provider.
as the active CP firmware, firmwareDownload has completed successfully on the blade. However, if
the firmwareCommit operation has been started to repair the secondary partition, at the end of
firmwareCommit, the blade firmware version may still be inconsistent with the active CP firmware.
In that case, firmwareDownload will automatically be restarted on the blade. Run the
firmwareDownloadStatus command to monitor the progress.