beautypg.com

Fcr-1018, Fcr-1019, Fcr-1020 – Dell POWEREDGE M1000E User Manual

Page 295

background image

Fabric OS Message Reference

219

53-1001767-01

FCR-1018

34

FCR-1018

Message

, [FCR-1018], ,, ERROR, , FC router

proxy device entries exhausted on port .

Probable Cause

Indicates that the number of proxy devices is greater than allowed by the port resource.

Recommended

Action

Remove excess logical storage area network (LSAN) zones or devices until the number of proxy
devices exported is within the range allowed by the port resource. Use the fcrResourceShow
command to view resources including LSAN zone resources, LSAN device resources, and proxy
device port resources.

Use the fcrProxyDevShow command to view how many proxy devices are created in the fabric with
the port resource problem.

LSAN zones are removed using standard zoning commands such as zoneShow, zoneRemove,
zoneDelete, cfgDelete, and cfgDisable in the edge fabric. Proxy devices can be removed by zoning
operations or by bringing physical devices offline. For example, disabling the port that a device is
attached to, and then disconnecting the cable or disabling the device.

Severity

ERROR

FCR-1019

Message

, [FCR-1019], ,, ERROR, , EX or VEX port

entries exhausted at port .

Probable Cause

Indicates that the number of EX_Port or VEX_Port entries being created is greater than allowed by
the port resource.

Recommended

Action

EX_Ports or VEX_Ports exceeding the specified range will automatically be disabled by the port
resource. Use the fcrRouteShow command to display the EX_Port or VEX_Port limits. Use the
portDisable command to disable EX_Ports.

Severity

ERROR

FCR-1020

Message

, [FCR-1020], ,, WARNING, , Local LSAN

zone entries for FC router exhausted; max limit: .

Probable Cause

Indicates that the number of logical storage area network (LSAN) zones created within a MetaSAN
exceeds the local LSAN zone database limitations.

Recommended

Action

Remove excess LSAN zones so that the number of LSAN zones created is within the range of local
database limitations.

To do that, perform the following steps:

1. Run the portDisable command to disable all the EX_Ports that got this error message.

2. Run the portDisable command to disable all the other EX_Ports on that FCR connected to the

same edge fabrics the EX_ports disabled in step 1 are connected to.