beautypg.com

Nsm-1005, Nsm-1006, Nsm-1007 – Dell POWEREDGE M1000E User Manual

Page 528: Nsm-1008

background image

452

Fabric OS Message Reference

53-1001767-01

NSM-1005

73

Recommended

Action

No action is required.

Severity

INFO

NSM-1005

Message

, [NSM-1005], ,, INFO, ,The FCoE VLAN:

is in use. First remove all the FCoE sessions of its member ports and

then try again to disable it.

Probable Cause

Indicates that the FCoE VLAN is used in FCoEd.

Recommended

Action

Disable FCoE VLAN by removing all the FCoE sessions from its member ports.

Severity

INFO

NSM-1006

Message

, [NSM-1006], ,, INFO, , FCoE on VLAN:

has been disabled successfully.

Probable Cause

Indicates that the FCoE is disabled on the VLAN.

Recommended

Action

No action is required.

Severity

INFO

NSM-1007

Message

, [NSM-1007], ,, INFO, , Chassis is

.

Probable Cause

Indicates the chassis is disabled or enabled.

Recommended

Action

No action is required.

Severity

INFO

NSM-1008

Message

, [NSM-1008], ,, INFO, , Blade .

Probable Cause

Indicates the blade is disabled or enabled.