HIL-1104
45
HIL-1104
Message
number> faulted, Probable Cause Indicates that the fan voltage is below threshold. Recommended Action Run the psShow command to verify the power supply status. Try to reseat the faulty fan field-replaceable units (FRUs) and power supply FRU to verify that they If the problem persists, replace the fan FRU or the power supply FRU as necessary. Severity ERROR HIL-1105 Message Probable Cause Indicates that the switch voltage is above threshold. This message is specific to nonbladed Recommended Action For the Brocade 200E, 3250, 3850, 4012, 4016, 4018, 4020, and 4024, the entire switch must For the Brocade 3900, replace the motherboard FRU. For the Brocade 4100 , 4900, 7500, and AP7600, if the 12 volt level is faulty, replace one or both Severity ERROR HIL-1106 Message Probable Cause Indicates that the switch voltage is below threshold. This message is specific to nonbladed Recommended Action For the Brocade 200E, 3250, 3850, 4012, 4016, 4018, 4020, and 4024, the entire switch must For the Brocade 3900, replace the motherboard FRU. For the Brocade 4100, 4900, 7500, and AP7600, if the 12 volt level is faulty, replace one or both Severity ERROR
are seated properly.
switches and is not applicable to the Brocade 24000 or 48000.
be replaced because these switches do not have field-replaceable units (FRUs).
power supplies; if any other voltage is faulty, replace the entire switch.
switches and is not applicable to the Brocade 24000 or 48000.
be replaced because these switches do not have field-replaceable units (FRUs).
power supplies; if any other voltage is faulty, replace the entire switch.