beautypg.com

Hil-1301, Hil-1302, Hil-1303 – Dell POWEREDGE M1000E User Manual

Page 450: Hil-1304

background image

374

Fabric OS Message Reference

53-1001767-01

HIL-1301

45

HIL-1301

Message

, [HIL-1301], ,, WARNING, , 1 blower

failed or missing. Replace failed or missing blower assembly immediately.

Probable Cause

Indicates that a fan field-replaceable unit (FRU) has failed or has been removed. This message is
often preceded by a low speed error message. This problem can cause the switch to overheat.

Recommended

Action

Replace the affected fan FRU immediately.

Severity

WARNING

HIL-1302

Message

, [HIL-1302], ,, WARNING, ,

blowers failed or missing. Replace failed or missing blower assemblies

immediately.

Probable Cause

Indicates that multiple fan field-replaceable unit (FRU)s have failed or are missing on a switch. This
message is often preceded by a low fan speed message.

Recommended

Action

Replace the affected fan FRUs immediately.

Severity

WARNING

HIL-1303

Message

, [HIL-1303], ,, ERROR, , One fan

failed. Replace failed fan FRU immediately.

Probable Cause

Indicates that a fan field-replaceable unit (FRU) has failed. This message is often preceded by a low
fan speed message.

Recommended

Action

Replace the faulty fan FRU immediately

Severity

ERROR

HIL-1304

Message

, [HIL-1304], ,, ERROR, , Two fans

failed. Replace failed fan FRUs immediately.

Probable Cause

Indicates that multiple fan field-replaceable units (FRUs) have failed. This message is often
preceded by a low fan speed message.

Recommended

Action

Replace the faulty fan FRUs immediately.