Fw-1164, Fw-1165, Fw-1166 – Dell POWEREDGE M1000E User Manual
Page 382

306
Fabric OS Message Reference
53-1001767-01
FW-1164
42
FW-1164
Message
Probable Cause
Indicates that the number of synchronization losses that the port experiences has changed. Loss of
synchronization errors frequently occur due to a faulty small form-factor pluggable (SFP) or cable.
Signal losses often create synchronization losses.
Recommended
Action
Check both ends of your cable connection. Verify that the cable and small form-factor pluggables
(SFPs) are not faulty.
If you continue to experience synchronization loss errors, troubleshoot your host bus adaptor (HBA)
and contact your switch service provider.
Severity
INFO
FW-1165
Message
is
Probable Cause
Indicates that the number of synchronization losses that the port experiences has fallen below the
low boundary. Loss of synchronization errors frequently occur due to a faulty small form-factor
pluggable (SFP) or cable. Signal losses often create synchronization losses.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation. A low number of synchronization losses means that the switch is functioning
normally.
Severity
INFO
FW-1166
Message
is
Probable Cause
Indicates that the number of synchronization losses that the port experiences has risen above the
high boundary. Loss-of-synchronization errors frequently occur due to a faulty small form-factor
pluggable (SFP) or cable. Signal losses often create synchronization losses.
Recommended
Action
Check both ends of your cable connection. Verify that the cable and small form-factor pluggables
(SFPs) are not faulty.
If you continue to experience loss-of-synchronization errors, troubleshoot your host bus adaptor
(HBA) and contact your switch service provider.
Severity
WARNING