Fabric OS Message Reference
225
53-1001767-01
FCR-1038
34
FCR-1038
Message
entries exceeded local fabric limits by
zone limit:
Probable Cause
Indicates that the number of cfg/zone/alias entries created in a local fabric is greater than the
local switch&apos zone database limitations.
Recommended
Action
Remove excess cfg/zone/alias entries so that the number of logical storage area network (LSAN)
zones created is within the range of the local database limitations.
Severity
WARNING
FCR-1039
Message
device entries for backbone LSAN exhausted.
Probable Cause
Indicates that the number of devices in the specified logical storage area network (LSAN) defined in
the backbone fabric is greater than allowed by the local LSAN zone database limitations.
Recommended
Action
Remove excess device entries from this LSAN zone until the number of devices is within the range
of the local LSAN zone database limitations.
Severity
INFO
FCR-1040
Message
deleted in the backbone fabric.
Probable Cause
Indicates that a proxy device created in the backbone fabric was deleted.
Recommended
Action
No action is required.
Severity
INFO
FCR-1041
Message
device removed in the backbone fabric.
Probable Cause
Indicates that a logical storage area network (LSAN) zone device within the backbone fabric was
removed.
Recommended
Action
No action is required.