FW-1379
42
Severity
WARNING
FW-1379
Message
between high and low boundaries(High=
is
Probable Cause
Indicates that the number of illegal commands has changed from a value outside of the acceptable
range to a value within the acceptable range. This counter tracks how many times commands
allowed only on the primary fabric configuration server (FCS) switch have been executed on a
non-primary FCS switch. There are many commands that can be executed only on the primary FCS
switch as well as one security command that can be executed only on a backup FCS switch. The
counter increments every time someone issues one of these commands on a switch where it is not
allowed.
Recommended
Action
No action is required.
Severity
INFO
FW-1400
Message
has changed(High=
Probable Cause
Indicates that the flash usage percentage has changed. Flash increases and decreases slightly
with normal operation of the switch. Excessive permanent increases can lead to future problems.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity
INFO
FW-1401
Message
below low boundary(High=
Probable Cause
Indicates that the flash usage percentage has fallen below the low boundary. Flash increases and
decreases slightly with normal operation of the switch. Excessive permanent increases can lead to
future problems.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity
INFO