AUTH-1034
4
Recommended
Action
Add the entity's world wide name (WWN) to the SCC policy and reinitialize authentication by using
the portDisable and portEnable commands or the switchDisable and switchEnable commands.
Severity
ERROR
AUTH-1034
Message
validate name
Probable Cause
Indicates that the specified entity name in the payload is not in the correct format.
Recommended
Action
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable
and switchEnable commands.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity
ERROR
AUTH-1035
Message
type> length in Probable Cause Indicates that a particular data field in the authentication message has an invalid length field. This Recommended Action Usually this problem is transient. The authentication might fail. Reinitialize authentication using the portDisable and portEnable commands or the switchDisable If the message persists, run the supportFtp command (as needed) to set up automatic FTP Severity ERROR AUTH-1036 Message Probable Cause Indicates that the switch received an unexpected authentication message. Recommended Action Usually this problem is transient. The authentication might fail. Reinitialize authentication using the portDisable and portEnable commands or the switchDisable If the message persists, run the supportFtp command (as needed) to set up automatic FTP
error usually relates to internal failure.
and switchEnable commands.
transfers; then run the supportSave command and contact your switch service provider.
and switchEnable commands.
transfers; then run the supportSave command and contact your switch service provider.