Fabric OS Message Reference

53-1001767-01

CVLC-1026

19

Severity

ERROR

CVLC-1026

Message

, [CVLC-1026], ,, INFO, , Some secondary

metadata missing for encrypted LUN configured with -newLUN option.\nContainer:

, Initiator: , LUN ID: .

Probable Cause

Indicates that the secondary metadata does not exist on all LBAs for a LUN that is configured with
--newLUN option.

Recommended

Action

No action is required.

Severity

INFO

CVLC-1027

Message

, [CVLC-1027], ,, ERROR, , Encrypted LUN

configured with -newLUN option does not contain any metadata.\nContainer:

container name>, Initiator: , LUN ID: .

Probable Cause

Indicates the metadata was corrupted.

Recommended

Action

No action is required.

Severity

ERROR

CVLC-1028

Message

, [CVLC-1028], ,, WARNING, , Not

starting auto rekey on LUN with uncompressible blocks 1-16.\nContainer:

container name>, Initiator: , LUN ID: .

Probable Cause

Indicates a warning event.

Recommended

Action

Perform a manual rekey on this LUN.

Severity

WARNING

CVLC-1029

Message

, [CVLC-1029], ,, WARNING, , Mirror LUN

is disabled as primary LUN is being rekeyed without splitting the

mirror.\nContainer: , Initiator: ,

LUN ID: .

Probable Cause