Recommended
Action
Enable the iSNS Client service on a single switch in the fabric using the fosConfig command. Refer
to the Fabric OS Command Reference for more information on this command.
Severity
WARNING
ICPD-1005
Message
configuration between local switch (
is out of sync. iSCSI login is not allowed.
Probable Cause
Indicates that iSCSI switches in the fabric have different configurations in AUTH, VT, or DD.
Recommended
Action
Synchronize the configuration in the fabric using the iscsiCfg command. Refer to the Fabric OS
Command Reference for more information on this command.
Severity
WARNING
ICPD-1006
Message
is
on the switch.
Probable Cause
Indicates the iSCSI service is enabled or disabled on the switch.
Recommended
Action
No action is required.
Severity
INFO
ICPD-1007
Message
is
on the switch.
Probable Cause
Indicates the iSNSC service is enabled or disabled on the switch.
Recommended
Action
No action is required.
Severity
INFO
ICPD-1008
Message
(
Probable Cause
Indicates the iSCSI switch is reachable or unreachable.