Fabric OS Message Reference

507

53-1001767-01

SEC-1025

90

SEC-1025

Message

, [SEC-1025], ,, ERROR, , Invalid IP

address

()

detected.

Probable Cause

Indicates a corruption occurred during the distribution of the security database. This can occur only
when the primary fabric configuration server (FCS) distributes the security database to the other
switches in the fabric, then local validation finds the error in the security database. This is a rare
occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.

Severity

ERROR

SEC-1026

Message

, [SEC-1026], ,, ERROR, , Invalid format

or character in switch member

.

Probable Cause

Indicates a corruption occurred during the distribution of the security database. This can occur only
when the primary fabric configuration server (FCS) distributes the security database to the other
switches in the fabric, then local validation finds the error in the security database. This is a rare
occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.

Severity

ERROR

SEC-1028

Message

, [SEC-1028], ,, ERROR, , No name is

specified.

Probable Cause

Indicates a corruption occurred during the distribution of the security database. This can occur only
when the primary fabric configuration server (FCS) distributes the security database to the other
switches in the fabric, then local validation finds the error in the security database. This is a rare
occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.

Severity

ERROR