Bl-1007, Bl-1008, Bl-1009 – Dell POWEREDGE M1000E User Manual
Page 137

Fabric OS Message Reference
61
53-1001767-01
BL-1007
7
BL-1007
Message
number>: blade state is inconsistent with EM. bl_cflags 0x slot_on Probable Cause Indicates that a failover occurred while a blade was initializing on the previously active control Recommended Action No action is required. The blade is reinitialized. Because reinitializing a blade is a disruptive Severity WARNING BL-1008 Message 2>. Probable Cause Indicates that the blade has experienced a hardware failure or was removed without following the Recommended Action Make sure that the blade is seated correctly. If the blade is seated correctly, restart or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. To If the message persists, replace the blade. Severity CRITICAL BL-1009 Message in slot timed out initializing the chips. Probable Cause Indicates that the blade has failed to initialize the application-specific integrated circuit (ASIC) Recommended Action Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. To
processor (CP).
operation and can stop I/O traffic, you might have to stop and restart the traffic during this process.
recommended removal procedure.
run this command root access is required. Run the diagPost command to ensure that Power-On
Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on
these commands.
chips.
run this command root access is required. Run the diagPost command to ensure that Power-On
Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on
these commands.