Em-1067, Em-1068, Em-1069 – Dell POWEREDGE M1000E User Manual
Page 241

Fabric OS Message Reference
165
53-1001767-01
EM-1067
22
Probable Cause
Indicates the previously incompatible Fabric OS or Storage Application Services (SAS) firmware has
been upgraded and is now compatible.
Recommended
Action
No action is required.
Severity
INFO
EM-1067
Message
synchronization of the system due to version incompatibility with standby CP.
Probable Cause
Indicates that the software version on the standby CP is not compatible with this software version.
Recommended
Action
Upgrade the software on the standby CP or downgrade the software on this CP.
Severity
WARNING
EM-1068
Message
Availability Service Management subsystem failed to respond. A required component
is not operating.
Probable Cause
Indicates that the HA subsystem has not returned a response within four minutes of the request
from the Environmental Manager. It usually indicates that some component has not started
properly or has terminated. The specific component that has failed might be indicated in other
messages or debug data. There are serious internal Fabric OS configuration or hardware problems
on the switch.
Recommended
Action
Reboot or power cycle the switch. If the message persists, collect switch information using the
supportsave command, and contact your switch service provider.
Severity
ERROR
EM-1069
Message
number> is being powered off. Probable Cause Indicates a blade is being intentionally powered off. Recommended Action No action is required. Severity INFO