Swch-1004, Swch-1005, Swch-1006 – Dell POWEREDGE M1000E User Manual
Page 700: Swch-1007

624
Fabric OS Message Reference
53-1001767-01
SWCH-1004
98
SWCH-1004
Message
failed during recovery, disabling slot =
.
Probable Cause
Indicates a blade has failed during failover or recovery.
Recommended
Action
On a Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn
command.
On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000,
7500, or AP7600 switch, reboot or power cycle the switch
Severity
ERROR
SWCH-1005
Message
failed during recovery, disabling slot =
.
Probable Cause
Indicates the Diag blade attach has failed during failover or recovery.
Recommended
Action
On a Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn
command.
On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000,
7500, or AP7600 switch, reboot or power cycle the switch.
Severity
ERROR
SWCH-1006
Message
out of sync: Standby CP (ver =
functionality. (active ver =
devices exist; Otherwise '0'. >).
Probable Cause
Indicates the standby control processor (CP) does not support N_Port ID Virtualization (NPIV)
functionality, but the switch has some NPIV devices logged into the fabric.
Recommended
Action
Load a firmware version on standby that supports NPIV functionality, using the firmwareDownload
command.
Severity
WARNING
SWCH-1007
Message
Probable Cause
Indicates the switch port is disabled due to the reason displayed in the message.