An system messages, Chapter 3, An-1001 – Dell POWEREDGE M1000E User Manual
Page 113: An-1002, An-1003, Chapter

Fabric OS Message Reference
37
53-1001767-01
Chapter
3
AN System Messages
AN-1001
Message
allocate memory:
Probable Cause
Indicates that the specified function has failed to allocate memory.
Recommended
Action
Check memory usage on the switch using the memShow command. Restart or power cycle the
switch.
Severity
ERROR
AN-1002
Message
initialize; rc =
Probable Cause
Indicates that the initialization of the 'trafd' daemon has failed.
Recommended
Action
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS
Command Reference Manual for more information on this command.
Severity
ERROR
AN-1003
Message
bottleneck at slot
seconds were affected. Avg. inter-frame time
Probable Cause
For an F_Port, it indicates that the attached device is slow in responding to frames going out of this
port. This latency may be inherent in the device or due to heavy workload on the device. For an
E_Port, it indicates a downstream primary bottleneck.
Recommended
Action
Find the Top Talkers in the egress direction from this port and apply Ingress Rate Limiting to one or
more of them.
Severity
WARNING