beautypg.com

Fw-1035, Fw-1036, Fw-1037 – Dell POWEREDGE M1000E User Manual

Page 366: Fw-1038

background image

290

Fabric OS Message Reference

53-1001767-01

FW-1035

42

FW-1035

Message

, [FW-1035], ,, WARNING, ,

above high boundary(High=, Low=). Current value is

.

Probable Cause

Indicates that the temperature of the small form-factor pluggable (SFP) has risen above the high
boundary. Frequent fluctuations in temperature might indicate a deteriorating SFP.

Recommended

Action

Replace the SFP.

Severity

WARNING

FW-1036

Message

, [FW-1036], ,, INFO, ,

between high and low boundaries(High=, Low=). Current value

is .

Probable Cause

Indicates that the temperature of the small form-factor pluggable (SFP) has changed from a value
outside of the acceptable range to a value within the acceptable range. Frequent fluctuations in
temperature might indicate a deteriorating SFP.

Recommended

Action

No action is required.

Severity

INFO

FW-1037

Message

, [FW-1037], ,, INFO, ,

has changed(High=, Low=). Current value is .

Probable Cause

Indicates that the receive power value of the small form-factor pluggable (SFP) has changed. The
receive performance area measures the amount of incoming laser to help you determine if the SFP
is in good working condition or not. If the counter often exceeds the threshold, the SFP is
deteriorating.

Recommended

Action

Incoming laser fluctuations usually indicate a deteriorating SFP. If this message occurs repeatedly,
replace the SFP.

Severity

INFO

FW-1038

Message

, [FW-1038], ,, WARNING, ,

below low boundary(High=, Low=). Current value is

.