Fw-1035, Fw-1036, Fw-1037 – Dell POWEREDGE M1000E User Manual
Page 366: Fw-1038

290
Fabric OS Message Reference
53-1001767-01
FW-1035
42
FW-1035
Message
above high boundary(High=
Probable Cause
Indicates that the temperature of the small form-factor pluggable (SFP) has risen above the high
boundary. Frequent fluctuations in temperature might indicate a deteriorating SFP.
Recommended
Action
Replace the SFP.
Severity
WARNING
FW-1036
Message
between high and low boundaries(High=
is
Probable Cause
Indicates that the temperature of the small form-factor pluggable (SFP) has changed from a value
outside of the acceptable range to a value within the acceptable range. Frequent fluctuations in
temperature might indicate a deteriorating SFP.
Recommended
Action
No action is required.
Severity
INFO
FW-1037
Message
has changed(High=
Probable Cause
Indicates that the receive power value of the small form-factor pluggable (SFP) has changed. The
receive performance area measures the amount of incoming laser to help you determine if the SFP
is in good working condition or not. If the counter often exceeds the threshold, the SFP is
deteriorating.
Recommended
Action
Incoming laser fluctuations usually indicate a deteriorating SFP. If this message occurs repeatedly,
replace the SFP.
Severity
INFO
FW-1038
Message
below low boundary(High=