Fw-1513, Fw-1514, Fw-1515 – Dell POWEREDGE M1000E User Manual
Page 425

Fabric OS Message Reference
349
53-1001767-01
FW-1513
42
Probable Cause
Indicates that the number of link failures that the port experiences has changed and dropped
below upper threshold boundary to a value within the acceptable range. Link loss errors occur
when a link experiences a loss of signal and fails. Both physical and hardware problems can cause
link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for
concurrent loss of synchronization errors and, if applicable, troubleshoot them.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity
INFO
FW-1513
Message
between(High=
Probable Cause
Indicates that the number of synchronization losses that the port experiences has changed and
crossed lower threshold boundary to a value within the acceptable range. Loss of synchronization
errors frequently occur due to a faulty small form-factor pluggable (SFP) or cable. Signal losses
often create synchronization losses.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity
INFO
FW-1514
Message