Fabric OS Message Reference

53-1001767-01

BL-1003

7

Severity

CRITICAL

BL-1003

Message

, [BL-1003], , FFDC, CRITICAL, ,

Faulting blade in slot

.

Probable Cause

Indicates a faulty blade in the specified slot number.

Recommended

Action

Make sure that the blade is seated correctly. If the blade is seated correctly, restart or power cycle
the blade.

Run the systemVerification command to verify that blade does not have hardware problems. To run
this command root access is required. Run the diagPost command to ensure that Power-On
Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on
these commands.

If the message persists, replace the blade.

Severity

CRITICAL

BL-1004

Message

, [BL-1004], , FFDC, CRITICAL, ,

Suppressing blade fault in slot

.

Probable Cause

Indicates that the specified blade experienced a failure but was not faulted due to a user setting.

Recommended

Action

Restart or power cycle the blade, using the slotPowerOff and slotPowerOn commands.

Run the systemVerification command to verify that the blade does not have hardware problems. To
run this command root access is required. Run the diagPost command to ensure that Power-On
Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on
these commands.

If the message persists, replace the blade.

Severity

CRITICAL

BL-1006

Message

, [BL-1006], ,, INFO, , Blade

number> NOT faulted. Peer blade experienced abrupt failure.

Probable Cause

Indicates that the errors (mostly synchronization errors) on this blade are harmless. Probably, the
standby control processor (CP) blade connected to the active CP blade has experienced transitory
problems.

Recommended

Action

Use the haShow command to verify that the standby CP is healthy. If problem persists remove and
reinstall the faulty blade.

Severity

INFO