Auth-1025, Auth-1026, Auth-1027 – Dell POWEREDGE M1000E User Manual
Page 121

Fabric OS Message Reference
45
53-1001767-01
AUTH-1025
4
Severity
ERROR
AUTH-1025
Message
during
Probable Cause
Indicates that the authentication process failed to get the expected information during the
specified authentication phase.
Recommended
Action
Usually this problem is transient. The authentication might fail.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable
and switchEnable commands.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity
ERROR
AUTH-1026
Message
get
Probable Cause
Indicates that the authentication failed to get device or host bus adaptor (HBA) information due to
an internal failure.
Recommended
Action
Usually this problem is transient. If the authentication failed, retry the login.
Reinitialize authentication using the switchDisable and switchEnable commands or the portDisable
and portEnable commands.
Severity
WARNING
AUTH-1027
Message
select
Probable Cause
Indicates that the authentication process failed to select an authentication value (that is, DH
Group, hash value, or protocol type) from a receiving payload for the specified authentication
phase. This indicates that the local switch does not support the specified authentication value.
Recommended
Action
Check the authentication configuration and reset the supported value if needed using the authUtil
command.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable
and switchEnable commands.