Bl-1015, Bl-1016 – Dell POWEREDGE M1000E User Manual
Page 140

64
Fabric OS Message Reference
53-1001767-01
BL-1015
7
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled.
If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors
are encountered again:
•
On the Brocade 24000, and 48000, replace the blade field-replaceable unit (FRU).
•
On the Brocade 3900, replace the motherboard FRU.
•
On the Brocade 200E, 3016, 3250, 3850, or 4100, 4012, 4016, 4018, 4024, 4900, 7500,
AP7600, and 5000, replace the switch.
Severity
ERROR
BL-1015
Message
number> port is faulted. status=0x Probable Cause Indicates that the port generated an excessive number of interrupts that might prove fatal to the Recommended Action Make sure to capture the console output during this process. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, reboot the switch. Run the systemVerification command to determine if there is a hardware error. To run this Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors • On the Brocade 24000, and 48000, replace the blade field-replaceable unit (FRU). • On the Brocade 3900, replace the motherboard FRU. • On the Brocade 200E, 3016, 3250, 3850, or 4100, 4012, 4016, 4018, 4024, 4900, 7500, Severity ERROR BL-1016 Message port Probable Cause Indicates that the specified blade port has failed to get enabled. Recommended Action Make sure that the blade is seated correctly. If the blade is seated correctly, restart or power cycle the blade.
switch operation. The port is disabled to prevent the CP from becoming too busy. The bport is the
blade port; this number might not correspond to a user port number.
command root access is required.
are encountered again:
AP7600, and 5000, replace the switch.