Fw-1045, Fw-1046, Fw-1047 – Dell POWEREDGE M1000E User Manual
Page 369

Fabric OS Message Reference
293
53-1001767-01
FW-1045
42
Probable Cause
Indicates that the transmit power value of the small form-factor pluggable (SFP) has changed from
a value outside of the acceptable range to a value within the acceptable range. The transmit
performance area measures the amount of outgoing laser to help you determine if the SFP is in
good working condition or not. If the counter often exceeds the threshold, the SFP is deteriorating.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity
INFO
FW-1045
Message
has changed(High=
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has changed. If the
supplied voltage of the SFP transceiver is outside of the normal range, this might indicate a
hardware failure.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation. Frequent messages indicate that you must replace the SFP.
Severity
INFO
FW-1046
Message
below low boundary(High=
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has fallen below the low
boundary.
Recommended
Action
Verify that your optical components are clean and function properly. Replace deteriorating cables
or SFPs. Check for damage from heat or age.
Severity
WARNING
FW-1047
Message
above high boundary(High=
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has risen above the high
boundary.
Recommended
Action
The supplied current of the SFP transceiver is outside of the normal range, indicating possible
hardware failure. If the current rises above the high boundary, you must replace the SFP.