beautypg.com

Cvlm system messages, Chapter 20, Cvlm-1001 – Dell POWEREDGE M1000E User Manual

Page 209: Cvlm-1002, Cvlm-1003, Cvlm-1004, Chapter

background image

Fabric OS Message Reference

133

53-1001767-01

Chapter

20

CVLM System Messages

CVLM-1001

Message

, [CVLM-1001], ,, ERROR, , Failed to

allocate memory: .

Probable Cause

Indicates that the specified function has failed to allocate memory.

Recommended

Action

Check the memory usage on the switch using the memShow command. Restart or power cycle the
switch.

Severity

ERROR

CVLM-1002

Message

, [CVLM-1002], ,, ERROR, , Failed to

initialize rc = .

Probable Cause

Indicates that an initialization of a module within the CVLMD has failed.

Recommended

Action

Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS
Command Reference Manual
for more information on this command.

Severity

ERROR

CVLM-1003

Message

, [CVLM-1003], ,, INFO, , Crypto device

configuration has been committed by switch .

Probable Cause

Indicates that the switch has committed a crypto device configuration.

Recommended

Action

No action is required.

Severity

INFO

CVLM-1004

Message

, [CVLM-1004], ,, WARNING, , Crypto

device configuration between local switch and peer

WWN> is out of sync. New encryption session is not allowed.