Fw-1432, Fw-1433, Fw-1434 – Dell POWEREDGE M1000E User Manual
Page 419

Fabric OS Message Reference
343
53-1001767-01
FW-1432
42
Recommended
Action
Replace the faulty or deteriorating fan field-replaceable units (FRUs).
Severity
WARNING
FW-1432
Message
change contributing factor WWN:
bad.
Probable Cause
Indicates that the switch status is not in a healthy state. This occurred because the number of
faulty world wide name (WWN) cards is greater than or equal to the policy set by the
switchStatusPolicySet command.
Recommended
Action
Replace the faulty WWN card.
Severity
WARNING
FW-1433
Message
change contributing factor CP: CP non-redundant.
Probable Cause
Indicates that the switch status is not in a healthy state. This occurred because the number of
faulty CPs is greater than or equal to the policy set by the switchStatusPolicySet command. The CPs
are non-redundant.
If you power cycle a Brocade 24000 chassis in dual-domain configuration, and then reset the
micro-switch of the active CP before the heartbeat is up, this will cause both CPs to come up in a
non-redundant state.
Recommended
Action
Run the firmwareShow command to verify that both CPs have compatible firmware levels. Run the
firmwareDownload command to install the same level of firmware to both CPs. Replace any faulty
CPs.
If you reset the micro-switch (the latch on the CP blade) on the active CP before the heartbeat was
up on a power cycle, and the CPs came up non-redundant, then you should reboot the CPs again to
clear the problem.
Severity
WARNING
FW-1434
Message
change contributing factor Blade:
blade failures.
Probable Cause
Indicates that the switch status is not in a healthy state. This occurred because the number of
blade failures is greater than or equal to the policy set by the switchStatusPolicySet command.