Em-1013, Em-1014, Em-1015 – Dell POWEREDGE M1000E User Manual
Page 229

Fabric OS Message Reference
153
53-1001767-01
EM-1013
22
Probable Cause
Indicates that a switch blade or nonbladed switch failed to transition from one state to another. It is
faulted. The specific failed target state is displayed in the message. There are serious internal
Fabric OS configuration or hardware problems on the switch.
Recommended
Action
On Brocade DCX, 24000 and 48000, try reseating the indicated field-replaceable unit (FRU). If the
message persists, restart or power cycle the switch. Run the systemVerification command to verify
that the switch does not have hardware problems. To run this command root access is required.
Refer to the Fabric OS Command Reference Manual for more information on this command.
If the message persists, replace the FRU.
Severity
CRITICAL
EM-1013
Message
update FRU information for
Probable Cause
Indicates that the environmental monitor (EM) was unable to update the time alive or the original
equipment manufacturer (OEM) data in the memory on a field-replaceable unit (FRU).
Recommended
Action
If you ran the fruInfoSet command, try the command again; otherwise, the update is automatically
attempted again. If it continues to fail, try reseating the FRU.
If the message persists, replace the FRU.
Severity
ERROR
EM-1014
Message
sensor on
Probable Cause
Indicates that the environmental monitor was unable to access the sensors on the specified
field-replaceable unit (FRU).
Recommended
Action
Try reseating the FRU. If the message persists, replace the FRU.
Severity
ERROR
EM-1015
Message
failed (
).
Probable Cause
Indicates that a problem was discovered when performing consistency checks during a warm boot.
Recommended
Action
Monitor the switch. If the problem persists, a reBoot or power cycle is required to resolve the
problem.