Ssm system messages, Chapter 96, Ssmd-1001 – Dell POWEREDGE M1000E User Manual
Page 673: Ssmd-1002, Ssmd-1003, Ssmd-1004, Chapter

Fabric OS Message Reference
597
53-1001767-01
Chapter
96
SSM System Messages
SSMD-1001
Message
allocate memory:
Probable Cause
Indicates that the specified function has failed to allocate memory.
Recommended
Action
Check the memory usage on the switch using the memShow command.
Restart or power cycle the switch.
Severity
ERROR
SSMD-1002
Message
initialize
Probable Cause
Indicates that an initialization of a module within the SSM has failed.
Recommended
Action
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS
Command Reference Manual for more information on this command.
Severity
ERROR
SSMD-1003
Message
semaphore mutex:
Probable Cause
Indicates that the specified function has failed to lock the mutex (semaphore).
Recommended
Action
Restart or power cycle the switch.
Severity
ERROR
SSMD-1004
Message
unlock semaphore mutex: