Fw system messages, Chapter 42, Fw-1001 – Dell POWEREDGE M1000E User Manual
Page 363: Fw-1002, Fw-1003, Chapter

Fabric OS Message Reference
287
53-1001767-01
Chapter
42
FW System Messages
FW-1001
Message
has changed(High=
Probable Cause
Indicates that the internal temperature of the switch has changed.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation. To prevent recurring messages, disable the changed alarm for this threshold.
Severity
INFO
FW-1002
Message
below low boundary (High=
Probable Cause
Indicates that the internal temperature of the switch has fallen below the low boundary.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation. Typically, low temperatures means that the fans and airflow of a switch are
functioning normally.
Verify that the location temperature is within the operational range of the switch. Refer to the
hardware reference manual for the environmental temperature range of your switch.
Severity
WARNING
FW-1003
Message
above high boundary(High=
Probable Cause
Indicates that the internal temperature of the switch has risen above the high boundary to a value
that might damage the switch.
Recommended
Action
This message generally appears when a fan fails. If so, a fan failure message accompanies this
message. Replace the fan field-replaceable unit (FRU).
Severity
WARNING