Bl-1030, Bl-1031, Bl-1032 – Dell POWEREDGE M1000E User Manual
Page 145: Bl-1033

Fabric OS Message Reference
69
53-1001767-01
BL-1030
7
BL-1030
Message
Virtualization/FC Fastwrite ports on the switch will be reset as part of the
firmware upgrade.
Probable Cause
Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be
upgraded and resulted in the cold upgrade. As part of the upgrade, all the GbE or Fibre Channel
over IP (FCIP) or Virtualization data elements or FC Fastwrite ports were reset.
Recommended
Action
No action is required.
Severity
INFO
BL-1031
Message
in internal port (slot
Use slotpoweroff/slotpoweron to recover the blade.
Probable Cause
Indicates that link timeout occurred in one of the backend internal ports.
Recommended
Action
Power cycle the blade or run the slotPowerOff and slotPowerOn commands.
Severity
CRITICAL
BL-1032
Message
number>,bitmap 0x (reason Probable Cause Indicates that back-end (non-user) ports have not come ONLINE within time limit. Recommended Action Restart or power cycle the blade. Run the systemVerification command to verify that the blade does Refer to the Fabric OS Command Reference for more information on the systemVerification Severity CRITICAL BL-1033 Message number>,bitmap 0x ports (state
not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST)
is enabled. If the message persists, replace the blade.
command.