Fw-1121, Fw-1122, Fw-1123 – Dell POWEREDGE M1000E User Manual
Page 374

298
Fabric OS Message Reference
53-1001767-01
FW-1121
42
•
Two switches with the same domain ID have connected to one another.
•
Two fabrics have joined.
•
An E_Port has gone offline.
•
A principal link has segmented from the fabric.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity
INFO
FW-1121
Message
has changed(High=
Probable Cause
Indicates that the number of domain ID changes has changed. Domain ID changes occur when
there is a conflict of domain IDs in a single fabric and the principal switch has to assign another
domain ID to the switch.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity
INFO
FW-1122
Message
below low boundary(High=
Probable Cause
Indicates that the number of domain ID changes has fallen below the low boundary. Domain ID
changes occur when there is a conflict of domain IDs in a single fabric and the principal switch has
to assign another domain ID to the switch. A low number of domain ID changes means that the
fabric is functioning normally.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity
INFO
FW-1123
Message
above high boundary(High=
Probable Cause
Indicates that the number of domain ID changes has risen above the high boundary. Domain ID
changes occur when there is a conflict of domain IDs in a single fabric and the principal switch has
to assign another domain ID to the switch.