beautypg.com

Ficn-1011, Ficn-1012, Ficn-1013 – Dell POWEREDGE M1000E User Manual

Page 318

background image

242

Fabric OS Message Reference

53-1001767-01

FICN-1011

35

Probable Cause

Indicates a Device Level Exception frame was received from the FICON Channel.

Recommended

Action

If there was a job or IO failure associated with this event, please contact your vendor's customer
support for assistance.

Severity

INFO

FICN-1011

Message

, [FICN-1011], ,, ERROR, ,

DevDiskIng:XRC Incorrect RRS SeqNum Rcvd Path=0x

DeviceDomain>8X8X Expected=0x

number that was expected from the device>4X Received=0x

that was actually received from the device>4X Oxid=0x4X.

Probable Cause

Indicates the Control Unit/device presented a Read Record Set Sequence number different from
the SDM's expected sequence number.

Recommended

Action

If there was an XRC volume or session suspended associated with this event, please contact your
vendor's customer support for assistance.

Severity

ERROR

FICN-1012

Message

, [FICN-1012], ,, ERROR, ,

DevDiskIng:Device level exception found for Path=0x

HostPort DeviceDomain>8X8X: Oxid=0x

that was reported in the Device Level Exception Frame>4X.

Probable Cause

Indicates a Device Level Exception frame received from the FICON DASD Control Unit.

Recommended

Action

If there was a job or IO failure associated with this event, please contact your vendor's customer
support for assistance.

Severity

ERROR

FICN-1013

Message

, [FICN-1013], ,, INFO, ,

DevDiskIng:Status=0x

state>2X received in odd state=0x2X from

Path=0x8X

DeviceAddr>8X sent LBY.

Probable Cause

Indicates that when the device sent the status in an incorrect state, the emulation processing
rejected the status with an LBY frame.

Recommended

Action

If there was a job or IO failure associated with this event, please contact your vendor's customer
support for assistance.