Bl-1020, Bl-1021, Bl-1022 – Dell POWEREDGE M1000E User Manual
Page 142

66
Fabric OS Message Reference
53-1001767-01
BL-1020
7
BL-1020
Message
out initializing the chips.
Probable Cause
Indicates that the switch has failed to initialize the application-specific integrated circuit (ASIC)
chips.
Recommended
Action
Restart or power cycle the switch.
Run the systemVerification command to verify that the switch does not have hardware problems. To
run this command root access is required. Run the diagPost command to ensure that Power-On
Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on
these commands.
If the message persists, replace the switch.
Severity
CRITICAL
BL-1021
Message
Number>, internal port retry initialization, initialization>. Probable Cause Indicates that the switch had internal ports not online and that the system is retrying to bring the Recommended Action No action is required. Severity INFO BL-1022 Message Switch DISABLED because internal ports were not ONLINE, number not ONLINE>. Probable Cause Indicates that the switch initiation failed because one or more of the internal ports was not online. Recommended Action Restart or power cycle the switch. Run the systemVerification command to verify that the switch does not have hardware problems. To Additional fault messages precede and follow this error, providing more information. See other If the message persists, replace the switch.
ports that failed back online.
The switch is faulted.
run this command root access is required. Run the diagPost command to ensure that Power-On
Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on
these commands.
error messages for recommended action.