Cvlc-1030, Cvlc-1031, Cvlc-1032 – Dell POWEREDGE M1000E User Manual
Page 207

Fabric OS Message Reference
131
53-1001767-01
CVLC-1030
19
Recommended
Action
Break the mirror and re-establish the mirror after rekey on primary LUN is complete.
Severity
WARNING
CVLC-1030
Message
may be out of sync with mirror LUN.\nContainer:
Initiator:
Probable Cause
Indicates the manual rekey was completed on primary LUN.
Recommended
Action
1. Make the target ports of the mirror LUN offline to hosts.
2. Re-establish the mirror.
3. Once the mirror is in sync, split the mirror.
4. Bring back the target ports of the mirror LUN online.
Severity
WARNING
CVLC-1031
Message
is restored from mirror LUN. LUN in read-only mode.\nContainer: name>, Initiator: Probable Cause Indicates a rekeyed primary LUN may have been restored from mirror LUN without synchronizing. Recommended Action 1. Create a new primary LUN. 2. Add it to its container with -newLUN option. 3. Using host based migration application, copy data from old to new primary LUN. Severity WARNING CVLC-1032 Message metadata for LUN has been restored.\nContainer: Initiator: Probable Cause Indicates the host I/Os to secondary metadata region. Recommended Action No action is required. Severity INFO