Fabric OS Message Reference

131

53-1001767-01

CVLC-1030

19

Recommended

Action

Break the mirror and re-establish the mirror after rekey on primary LUN is complete.

Severity

WARNING

CVLC-1030

Message

, [CVLC-1030], ,, WARNING, , Primary LUN

may be out of sync with mirror LUN.\nContainer: ,

Initiator: , LUN ID: .

Probable Cause

Indicates the manual rekey was completed on primary LUN.

Recommended

Action

1. Make the target ports of the mirror LUN offline to hosts.

2. Re-establish the mirror.

3. Once the mirror is in sync, split the mirror.

4. Bring back the target ports of the mirror LUN online.

Severity

WARNING

CVLC-1031

Message

, [CVLC-1031], ,, WARNING, , Primary LUN

is restored from mirror LUN. LUN in read-only mode.\nContainer:

name>, Initiator: , LUN ID: .

Probable Cause

Indicates a rekeyed primary LUN may have been restored from mirror LUN without synchronizing.

Recommended

Action

1. Create a new primary LUN.

2. Add it to its container with -newLUN option.

3. Using host based migration application, copy data from old to new primary LUN.

Severity

WARNING

CVLC-1032

Message

, [CVLC-1032], ,, INFO, , Secondary

metadata for LUN has been restored.\nContainer: ,

Initiator: , LUN ID: .

Probable Cause

Indicates the host I/Os to secondary metadata region.

Recommended

Action

No action is required.

Severity

INFO