Cvlm-1005, Cvlm-1006, Cvlm-1007 – Dell POWEREDGE M1000E User Manual
Page 210: Cvlm-1008

134
Fabric OS Message Reference
53-1001767-01
CVLM-1005
20
Probable Cause
Indicates that EE nodes in the cluster encryption group have different configurations.
Recommended
Action
Synchronize the configuration in the cluster group using the cryptocfg --commit command. Refer to
the Fabric OS Command Reference Manual for more information on this command.
Severity
WARNING
CVLM-1005
Message
is
Probable Cause
Indicates that Crypto service is enabled or disabled on the switch.
Recommended
Action
No action is required.
Severity
INFO
CVLM-1006
Message
device
Probable Cause
Indicates that the crypto device in the crypto target container is not in AD0.
Recommended
Action
Use the ad command to move the crypto device into AD0. Refer to the Fabric OS Command
Reference Manual for more information on this command.
Severity
WARNING
CVLM-1007
Message
zone update failure. Status is
Probable Cause
Indicates that the redirect zone update has failed.
Recommended
Action
Issue the cryptocfg --commit command again. Refer to the Fabric OS Command Reference Manual
for more information on this command.
Severity
WARNING
CVLM-1008
Message
Probable Cause
Indicates that the member of HAC is not in the fabric.