beautypg.com

L2ss-1005, L2ss-1006, L2ss-1007 – Dell POWEREDGE M1000E User Manual

Page 494

background image

418

Fabric OS Message Reference

53-1001767-01

L2SS-1005

60

Recommended

Action

Restart the l2sysd daemon.

Severity

ERROR

L2SS-1005

Message

, [L2SS-1005], ,, ERROR, ,

Mac-address-table hash failed even after two attempts for slot chip .

Probable Cause

Indicates a mac-address-table hash failure happened even after two hash changes on the chip.

Recommended

Action

Restart the l2sysd daemon.

Severity

ERROR

L2SS-1006

Message

, [L2SS-1006], ,, INFO, ,

Mac-address-table table on slot chip is 95 percent full.

Probable Cause

Indicates that the mac-address-table on the chip is 95% full.

Recommended

Action

Clear some of the entries, or wait till old entries age out.

Severity

INFO

L2SS-1007

Message

, [L2SS-1007], ,, INFO, ,

MMac-address-table on slot chip is less than 90 percent full.

Probable Cause

Indicates that the mac-address-table is less than 90% full.

Recommended

Action

No action is required. L2SYS will start learning the entries.

Severity

INFO