Fabric OS Message Reference

317

53-1001767-01

FW-1201

42

Probable Cause

Indicates that the number of C3 transmit time out frames has changed.

Recommended

Action

Check the target device; it could be slow.

Severity

INFO

FW-1201

Message

, [FW-1201], ,, INFO, , ,

value is .

Probable Cause

Indicates that the number of C3 transmit time out frames is below low threshold.

Recommended

Action

Respond to this message as it is appropriate to the particular policy of the end-user installation. A
low number of C3 discard means that the switch is functioning normally.

Severity

INFO

FW-1202

Message

, [FW-1202], ,, WARNING, , ,

value is .

Probable Cause

Indicates that the number of C3 transmit time out frames is above high threshold.

Recommended

Action

Check the target device; it could be slow.

Severity

WARNING

FW-1203

Message

, [FW-1203], ,, INFO, , ,

Current value is .

Probable Cause

Indicates that the number of C3 transmit time out frames is between high and low thresholds.

Recommended

Action

Check the target device; it could be slow.

Severity

INFO