Sysm system messages, Chapter 100 sysm system messages, Sysm-1001 – Dell POWEREDGE M1000E User Manual
Page 707: Sysm-1002, Sysm-1003, Chapter

Fabric OS Message Reference
631
53-1001767-01
Chapter
100
SYSM System Messages
SYSM-1001
Message
memory.
Probable Cause
Indicates the switch has run out of system memory.
Recommended
Action
Run the memShow command to view the switch memory usage.
Restart or power cycle the switch.
Run the supportFtp command to set up automatic FTP transfers; then run the supportSave
command and contact your switch service provider.
Severity
CRITICAL
SYSM-1002
Message
Switch:
Probable Cause
Indicates a user has executed either the switchShutdown or switchReboot command. All services
are brought down for a logical switch.
Recommended
Action
No action is required if the switchShutdown or switchReboot command was executed intentionally.
If the switchShutdown command was run, you must run the switchStart command to restart traffic
on the logical switch.
Severity
INFO
SYSM-1003
Message
Switch:
Probable Cause
Indicates the user executed the switchStart or switchReboot command. This indicates that all
services are brought back up after a temporary shutdown of that logical switch.
Recommended
Action
No action is required if the switchStart command was executed intentionally. Because reinitializing
a switch is a disruptive operation and can stop I/O traffic, you might have to stop and restart the
traffic during this process.
Severity
INFO