EM-1006
22
EM-1006
Message
Id> has faulted. Sensors below minimum limits. Probable Cause Indicates that the sensors show the voltage is below minimum limits. The switch or specified blade Recommended Action If this problem occurs on a blade, it usually indicates a hardware problem on the blade; replace the If this problem occurs on a switch, it usually indicates a hardware problem on the main board; Severity CRITICAL EM-1007 Message Id> is being reset. Sensors has exceeded max limits. Probable Cause Indicates that the voltage on a switch has exceeded environmental limits. A reset is sent to the Recommended Action There is most likely a voltage hardware problem on the blade or motherboard of the switch. For the Brocade DCX, 24000 and 48000, replace the blade field-replaceable unit (FRU). For the Brocade 3900 replace the motherboard FRU. For the Brocade 200E, 3016, 3250, 3850, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000, Severity CRITICAL EM-1008 Message Probable Cause Indicates that a blade inserted in the specified slot or the switch (for nonbladed switches) is not Recommended Action If the blade is not compatible, replace the blade and ensure the replacement blade is compatible Severity CRITICAL
is being shut down for environmental reasons; the voltage is too low.
blade.
replace the switch.
faulty slot or the switch for nonbladed switches.
7500, AP7600, replace the switch.
compatible with either the platform configuration or the logical switch configuration. The blade is
faulted.
with your control processor (CP) type. If the incompatibility is with the logical switch configuration,
change the configuration with the lscfg command to be consistent with the blade type or remove
the blade.