beautypg.com

Fcr-1042, Fcr-1043, Fcr-1048 – Dell POWEREDGE M1000E User Manual

Page 302: Fcr-1049

background image

226

Fabric OS Message Reference

53-1001767-01

FCR-1042

34

Severity

INFO

FCR-1042

Message

, [FCR-1042], ,, INFO, , LSAN zone

removed in the backbone fabric.

Probable Cause

Indicates that a logical storage area network (LSAN) zone within the backbone fabric was removed.

Recommended

Action

No action is required.

Severity

INFO

FCR-1043

Message

, [FCR-1043], ,, INFO, , Proxy device

created in the backbone fabric.

Probable Cause

Indicates that a proxy device was created in the backbone fabric.

Recommended

Action

No action is required.

Severity

INFO

FCR-1048

Message

, [FCR-1048], ,, ERROR, , On EX port

() setting port credits failed.

Probable Cause

Indicates that the specified credit type was not set.

Recommended

Action

Setting port credits failed. Execute the portEnable command.

If the problem persists try restarting the switch.

If the message persists, collect switch information using the supportShow command, and contact
your switch service provider.

Severity

ERROR

FCR-1049

Message

, [FCR-1049], ,, ERROR, , EX port (

number>

) received an ELP command that is not supported.

Probable Cause

Indicates an incoming exchange link protocol (ELP) command was issued and it is not supported.