Em-1048, Em-1049, Em-1050 – Dell POWEREDGE M1000E User Manual
Page 237

Fabric OS Message Reference
161
53-1001767-01
EM-1048
22
Probable Cause
Indicates that the control processor (CP) is no longer faulted. This message usually follows
EM-1033. The new standby CP is in the process of rebooting and has turned off the CP_ERR signal.
Recommended
Action
No action is required.
Severity
INFO
EM-1048
Message
access recovered: state
Probable Cause
Indicates that the I2C bus problems have been resolved and I2C access to the field-replaceable
unit (FRU) has become available again.
Recommended
Action
The EM-1029 error can be a transitory error; if the problem resolves, the EM-1048 message is
displayed.
Severity
INFO
EM-1049
Message
insertion detected.
Probable Cause
Indicates that a field-replaceable unit (FRU) of the type and location specified by the FRU ID was
detected as having been inserted into the chassis.
Recommended
Action
No action is required.
Severity
INFO
EM-1050
Message
removal detected.
Probable Cause
Indicates that a field-replaceable unit (FRU) of the specified type and location was removed from
the chassis.
Recommended
Action
Verify that the FRU was intended to be removed. Replace the FRU as soon as possible.
Severity
INFO