beautypg.com

Ag-1015, Ag-1016, Ag-1017 – Dell POWEREDGE M1000E User Manual

Page 105: Ag-1018

background image

Fabric OS Message Reference

29

53-1001767-01

AG-1015

2

Severity

INFO

AG-1015

Message

, [AG-1015], ,, WARNING, , Unable to

find online N_Ports to connect to the fabric.

Probable Cause

Indicates either no other N_Port is configured or all N_Ports are currently offline.

Recommended

Action

Check whether or not any other N_Port is configured.

If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportsave command and contact your switch service provider.

Severity

WARNING

AG-1016

Message

, [AG-1016], ,, INFO, , Failing over

F_Ports mapped to N_Port to other N_Ports.

Probable Cause

Indicates the specified N_Port has failed to come online. All F_Ports mapped to this N_Port are
being failed over to other active N_Ports.

Recommended

Action

Run the ag --mapShow command to display updated F_Port-to-N_Port mapping.

Severity

INFO

AG-1017

Message

, [AG-1017], ,, WARNING, , No N_Ports

are currently Online.

Probable Cause

Indicates no N_Ports are currently configured in the system or all configured N_Ports have failed to
come online.

Recommended

Action

Run the switchShow command to display the status of all ports in the system. Run the portCfgShow
command to display a list of ports currently configured as N_Ports.

Severity

WARNING

AG-1018

Message

, [AG-1018], ,, ERROR, , Host port

should not be connected to port , which is configured as N_Port.

Probable Cause

Indicates that an Initiator or Target is erroneously connected to a port configured for N_Port
operation.