Sec-1119, Sec-1121, Sec-1122 – Dell POWEREDGE M1000E User Manual
Page 606: Sec-1123

530
Fabric OS Message Reference
53-1001767-01
SEC-1119
90
Recommended
Action
Usually this problem is transient. Retry the command.
Severity
INFO
SEC-1119
Message
been enabled.
Probable Cause
Indicates the secure Fabric OS was enabled by the secModeEnable command.
Recommended
Action
Verify the security event was planned. If the security event was planned, there is no action required.
If the security event was not planned, take appropriate action as defined by your enterprise security
policy.
Severity
INFO
SEC-1121
Message
range when
.
Probable Cause
Indicates the time on the switch is not synchronized with the primary fabric configuration server
(FCS), the data packet is corrupted, or a replay attack is launched on the switch.
Recommended
Action
Verify the security event was planned. If the security event was planned, verify that all switches in
the fabric are in time synchronization with the primary FCS and that no external entity is trying to
access the fabric. When verification is complete, retry the operation.
Severity
ERROR
SEC-1122
Message
Probable Cause
Indicates that one of the switches in the fabric could not communicate with the primary fabric
configuration server (FCS).
Recommended
Action
Run the secFabricShow command to verify that all switches in fabric are in the ready state. When
all switches are in the ready state, retry the operation.
Severity
INFO
SEC-1123
Message
database downloaded by Primary FCS.