Ssmd-1202, Ssmd-1203, Ssmd-1204 – Dell POWEREDGE M1000E User Manual
Page 675: Ssmd-1205

Fabric OS Message Reference
599
53-1001767-01
SSMD-1202
96
SSMD-1202
Message
programming interface 0x
Probable Cause
Indicates the DCE System Services Manager (SSM) encountered an unexpected error in
programming the dataplane ASIC for enforcing the interface 802.3x Pause flow control feature.
Recommended
Action
Delete and reapply QoS 802.3x Pause flow control policy. Restart or power cycle the switch.
Severity
WARNING
SSMD-1203
Message
programming interface 0x
Probable Cause
Indicates the DCE System Services Manager (SSM) encountered an unexpected error in
programming the dataplane ASIC for enforcing the interface PFC flow control feature.
Recommended
Action
Delete and reapply QoS 802.3x Pause flow control policy. Restart or power cycle the switch.
Severity
WARNING
SSMD-1204
Message
initializing ASIC
Probable Cause
Indicates the DCE System Services Manager (SSM) encountered an unexpected error in initializing
the dataplane ASIC QoS infrastructure.
Recommended
Action
Restart or power cycle the switch.
Severity
WARNING
SSMD-1205
Message
programming ETS policy for CEE Map
Probable Cause
Indicates the DCE System Services Manager (SSM) encountered an unexpected error in
programming the dataplane ASIC for enforcing the CEE Map ETS feature.
Recommended
Action
Delete and reapply the CEE Map ETS policy. Restart or power cycle the switch.