Fw-1004, Fw-1009, Fw-1010 – Dell POWEREDGE M1000E User Manual
Page 364: Fw-1011

288
Fabric OS Message Reference
53-1001767-01
FW-1004
42
FW-1004
Message
between high and low boundaries(High=
is
Probable Cause
Indicates that the internal temperature of the switch has changed from a value outside of the
acceptable range to a value within the acceptable range.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity
INFO
FW-1009
Message
has changed(High=
Probable Cause
Indicates that the state of the power supply has changed from faulty to functional, or from
functional to faulty.
Recommended
Action
If the power supply is functioning correctly, no action is required.
If the power supply is functioning below the acceptable boundary, verify that it is seated correctly in
the chassis. Run the psShow command to view the status of the power supply. If the power supply
continues to be a problem, replace the faulty power supply.
Severity
INFO
FW-1010
Message
below low boundary(High=
Probable Cause
Indicates that the power supply is faulty. The power supply is not producing enough power.
Recommended
Action
Verify that you have installed the power supply correctly and that it is correctly seated in the
chassis. If the problem persists, replace the faulty power supply.
Severity
WARNING
FW-1011
Message
above high boundary(High=
Probable Cause
Indicates that the power supply is functioning properly.